The Rechargeable Hair dryer (hair dryer)
high
discharge lithium battery discharge board(CIRCUIT DESIGN)
Self-protection circuit and the characteristics of lithium batteries as
follows:
Lithium-ion
battery protection circuit includes over-charge protection, over
current / short circuit protection and over-discharge protection, small
size lithium batteries, high energy density, is the best power storage,
but also has its shortcomings that require special attention.
In
recent years, more and more to carry goods, most use lithium batteries
as main power. Li-ion battery with no memory effect, high cycle life,
high-voltage battery and low self-discharge, etc., and nickel-cadmium,
nickel metal hydride batteries are not the same, lithium batteries must
consider the charge, discharge of security features to prevent
deterioration. A process not pay attention to, lithium batteries will
experience a qualitative change of the damage.
Lithium-ion battery protection circuit is to ensure that the following
conditions can be monitored:
Overcharge protection
Over-charging
protection circuit principle: When an external charger for lithium
batteries, in order to prevent the voltage input exceeds the rated
capacity, resulting in changes in battery materials. Protection circuit
needs to be cut off the action, to prevent the continued input voltage
battery charger This voltage threshold value, need sophisticated
battery specifications.
Charging too long protection
Charging too
long to protect the principle is: When
the characteristics of the battery can
only charge to a certain voltage, if
the constant sink current of the battery, a
battery deterioration concerns, the need
to consider charging the whole time,
and sophisticated battery specifications.
Over-discharge protection
In
the case of excessive discharge, caused by decomposition of the
electrolyte cell characteristics due to deterioration, reduced number
of charge cycles and cause. Battery discharge protection circuit to
avoid using excessive discharge phenomenon, to achieve cell protection.
In
order to prevent excessive battery discharge status, assuming that the
lithium battery connected to the load when the battery voltage is lower
than the over-discharge voltage test point (assumed to be 2.3V) will
start over-discharge protection, cut off the output power.
When
the lithium battery charger connected again, and this time the basis of
voltage lithium battery voltage is present, the normal discharge to the
battery charger.
Over current and short circuit current
For
unknown reasons (positive and negative discharge or by metal objects
inadvertently) caused by over-current or short circuit, to ensure
safety, the protection circuit must immediately cease its discharge.
|

|
|
|
|
 Dian-Deng/ACEUP
TECHNOLOGY CO., LTD/R.O.C. Registeration NO: 53330825
 Contact
Address: 5F.,
No.611, Sec. 1, Neihu Rd., Neihu Dist., Taipei City 114, Taiwan
(R.O.C.)
 TEL:+886-2-2627-4767  E-MAIL:
service@dian-deng.com
PROFESSIONAL
DEVELOPMENT OF ELECTRONIC CIRCUITS LAYOUT DESIGN - PROFESSIONAL
SOFTWARE FIRMWARE DEVELOPMENT - PROFESSIONAL SOFTWARE LOGICAL LAYOUT -
PROFESSIONAL SINGLE CHIP / MCU / MICROPROCESSOR DEVELOPMENT -
PROFESSIONAL PROOFING DESIGN - PROFESSIONAL-VOLUME PRODUCT DEVELOPMENT
- PRODUCTION ADVICE AND ASSISTANCE
TEST THE SYSTEM WITH THE PRODUCTION - LIFE APPLICATION ELECTRONIC -
VOLTAGE / CURRENT / CHARGE / DISCHARGE INTEGRATION OF THE LAYOUT -
DESIGN COSTS REASONABLE - CONSULTATION SEEKING LONG-TERM PARTNERS - TO
REDUCE DEVELOPMENT COSTS
|
|